Car Alarms: no start w/micro 8008-99, cold outdoors, starter relay


Question
Can we bypass the micro 8008-99 to rule it out as the cause of a COLD no start condition?  If so how do we do it?  Where do we locate a schematic for the 8008-99.  This is a 2004 Dodge Ram 4.8liter V8.  It won't start when COLD outdoors, but will start when warm(afternoon).  Batt and starter relay have been replaced(did not help).  Most ground terminal have been cleaned.  Batt terminals have been cleaned.  Would like to bypass the 8008 to be sure it is not the cause of the cold no start condition.  thanks bennie

Answer
Ok, this is an alarm and keyless system with
optional starter kill capability.

Get the manual in the support section
at www.microalarm.com but this would
only affect the truck if there was a starter
kill relay installed. The 8008 does have
an output available for it, but a relay would have
had to been installed for it to cause
a starter disable in this case.

It is likely as not, to be a fault in the
charging system or computer system if the
Micro does not have the 0range (-) output
being used.

Good luck with your trouble shooting.

ALARMTEK
CARALARMMAN.COM