Chrysler Repair: 96 grand voyager, calibration test, postal mail


Question
hi doug again,
  i replaced the resistor block now the blower motor works great. i also ran the  
CALIBRATION/DIAGNOSTICS TEST and when it was done only the rear wiper light was flashing. i hit the button to get out of the test and the rear wiper lights are no longer flashing
hoary for now but it never ran the cool down test only the first part ran( Calibration Test is running when REAR WIPER and INTERMITTENT are alternately flashing. ) how do i run the cool down test? right now after the test the only lights that are blinking are the A/C and RECIRC lights they blink steady and together at the same time.

Answer
Hi Doug,
To test the cooldown, Set blower on High, set mode to Panel, open all AC outlets, set temp(s) to cold, depress wash and A/C simultaneously for 5 seconds. (The evaporator should not be cold already, so turn off the AC and run for 3 minutes with the blower on High before starting)
All LED's will turn on for 5 seconds. The test is running if A/C and recirc are alternatively flashing. If A/C and recirc are flashing simultaneously the cooldown tests has failed.
I can't recall if you have all the instructions for reading out the codes. But it is so extensive that if you need them I would prefer to copy and postal mail them to you.
Roland
PS Again, press the thank/rate tab to get back to me. If this is helpful please consider a 'nomination'.
Roland