Jeep Repair: A/C question, negative battery cable, jeep wrangler


Question
I have a 06 jeep wrangler and i notice that on the passanger side i had a receipt flying around and it was sucked up under the Dash board. Now when I turn on the AC i can here it restricted the flow. I tried to see if there is a open fan it could have gotten in to but could not find one. Any ideas what might of sucked it up and how do i get it out.
thank you

Answer
REMOVAL
WARNING:  On vehicles equipped with airbags, disable the airbag system before attempting any steering wheel, steering column, or instrument panel component diagnosis or service. Disconnect and isolate the battery negative (ground) cable, then wait two minutes for the airbag system capacitor to discharge before performing further diagnosis or service. This is the only sure way to disable the airbag system. Failure to take the proper precautions could result in an accidental airbag deployment and possible personal injury or death.  




NOTE:  The blower motor is located on the passenger side of the vehicle under the instrument panel. The blower motor can be removed without having to remove the instrument panel or the HVAC housing.  
1. Disconnect and isolate the negative battery cable.

2. Disconnect the wire harness connector from the blower motor Fig. 1 .
3. Release the locking tab that secures the blower motor to the HVAC housing and rotate blower motor counterclockwise.
4. Rotate and tilt the blower motor as needed for clearance to remove the blower motor and wheel from the HVAC housing.


Fig. 1 - Blower Motor - LHD shown, RHD similar  
1 - HVAC HOUSING  
2 - BLOWER MOTOR  
3 - RETAINER-LOCKING TAB  
4 - WIRE HARNESS CONNECTOR