Question
My craftsman riding mower will crank and run for anywhere from 5 minutes to 20 minutes and just quit.  It will immediately crank up again and run for a few minutes and quit again.  What could be causing this. thanks phillip

Answer
Hello Phillip:

I Usually Suggest you Check the Following in this Order for a Problem like yours. 1- Check the Gas Tank Cap and Ensure it is Venting the Tank. A Vacuum Builds in the Tank and the Gas Flow Stops or Slows to a Point it Shuts Off the Engine. 2- Operate the Equipment Until it Quits (15 to 20min). Then Immediately Check for Fire from the Plug. If the Plug is Firing, then 3- Check the Carburetor Solenoid. If the Carburetor Shut Off Solenoid has Current, then Remove the Carburetor Solenoid and Go to the Hardware Store. Purchase a Bolt of the Same Diameter and Threads. It Needs to be 3/4" Long. Put this Bolt in Place of the Solenoid. If this Corrects the Engine Problem, then Replace the Solenoid. ***NOTE: THIS IS FOR CHECKING THE SOLENOID ONLY I NEVER SUGGEST YOU OPERATE THE ENGINE WITH THE SOLENOID OUT OF THE CARBURETOR EXCEPT FOR TESTING PURPOSES*** Sometimes the Plunger is Moving, Just Not Far Enough to Allow the Gas to Enter the Jets. 4- Depending on the Model Mower, it can Also be the Pickup Tube in the Gas Tank. If you Hit a Snag or this Does Not Correct the Problem,  I am Here if You Require More Assistance. Hope this Helps. Let me Know What Happens, Please. May the All Mighty Bless You and Yours. Thanks.

Good Luck

Respectfully

John

PS: I am Allowed to Answer 10 Questions a Day. If you See I am Maxxed Out, then Try Submitting your Question at or Just After 8pm EST (US). My New Day Starts then. Thanks.

Respectfully

John