Small Engines (Lawn Mowers, etc.): Deere L120, switch jumper, jumper wire


Question
I just went back out to the garage for round 2 of snow plowing and I turn the key and nothing. Headlight is bright, 20a fuse is good. Now if I jump the solenoid with a screw driver the engine turns and I smelled gas but it doesn't seem to be getting spark. I tried it again this time with a spark plug attached to the right cyl plug wire and held it close to the frame and no spark. Any ideas would be very helpful.

Thanks,
Mike


Answer
Hello Mike:

From your Description it Sounds like a Safety Switch is Bad. **PLEASE REMEMBER THAT THE INSTRUCTIONS FOR CHECKING THE SAFETY SWITCHES IS JUST THAT!!! FOR CHECKING ONLY. I NEVER Suggest a Mower be Operated with a Safety Device or Switch Disconnected or Bypassed. Now. On Some Model Mowers you can Simply Unplug the Safety Switch from the Harness. On Other Models you have to Place a Jumper Wire Between the Harness Terminals (on the 4 Post Switch Jumper from Same Color Wire to Same Color Wire). Check the Clutch/Break and the Blade/PTO Safety Switches First. Some Models have a Transaxle Neutral Safety Also. Check the Seat Safety Last. Usually the Seat Safety is Not in the System for Starting the Engine. Just to Ensure Someone is in the Seat when Engaging the Transaxle and/or Blades.** You can View a Breakdown/IPL of the Engine and Mower at this Site Addy, http://jdpc.deere.com/jdpc/servlet/com.deere.u90490.partscatalog.view.servlets.H... and Enter the Model Numbers and Click Find. Then Select the Sectional File. Then Select the Section of the Mower you Wish to View Online. If you Hit a Snag or this Does Not Correct the Problem,  I am Here if You Require More Assistance. Hope this Helps. Let me Know What Happens, Please. May the All Mighty Bless You and Yours. Thanks.

Good Luck

Respectfully

John

PS: I am Allowed to Answer 10 Questions a Day. If you See I am Maxxed Out, then Try Submitting your Question at or Just After 8pm EST (US). My New Day Starts then. Thanks.

Respectfully

John