Car Alarms: 94 accord keyless entry, volt source, wire colors


Question
QUESTION: Hello there I'm installing a keyless entry in my 1994 honda accord the door trigger on the diagram has two wires a negative and positive my door triggers are negative so do I leave the grn/blk positive wire alone or do I ground it? Also do u have any idea how starter kill relays work?

ANSWER: If it's only a keyless entry, disregard the
"door triggers" alltogther. It's a 3 wire
NEGATIVE door lock system.

See starter disable at www.relayhelp.com
if you need one of my diagrams.

Have a good eve.

ALARMTEK

---------- FOLLOW-UP ----------

QUESTION: Oh sorry I forgot 2 mention I'm doing the alarm as well and that's where I'm stumped about that positive wire also the parking light has 2 positive wires but my car has 1 so I just dropp one correct? And sense its a 3 wire negative then I don't need relays I can just hook the white/ and white and black c.o.m from alarm right up to the white and orange from the car?

Answer
no idea on he wire colors, follow the directions on that.
cut the positive door trigger wire. not used in this car.
The parking light wire may have a polarity shifting wire
which it sound like you have there.
One would go to the parking light wire,
the other to a positive fused 12 volt source.
If it were a negative type parking light like in
some dodges now, the purple that is going to the
fused 12 volts source, would go to ground.