Dodge Repair: 98 Dodge Caravan, slide pots, dodge caravan


Question
Although the car runs fine the heater control panel lights flash.  What cause the heater control panel to flash and how can I reset it?
Thanks, Stephen

Answer
U just put a battery in?? here is how t recal the system.
I live in the Atlanta area I would be glad to look at it for u.

COOLDOWN TEST ENTRY
TO INITIATE TESTS:
Set Blower motor ON HIGH
Set Mode position to Panel
Open all A/C outlets
Set Temperature to Cold (Both slide pots if equipped)
Depress WASH and A/C simultaneously for 5 Seconds
NOTE: Prior to start of test, If the evaporator is already cold, the system will fail test. To correct, operate system with A/C OFF and the blower motor ON high for three minutes prior to starting test.

RESULTS:
All LED's will turn on for 5 Seconds
Cooldown Test is running when A/C and RECIRC. are alternately flashing. If A/C and RECIRC. are flashing simultaneously, Cooldown has failed.