Hi
I have a Sabre 1438HS lawn tractor that's about 8 years old with a 14.5 hp Briggs and Stratton engine. The mower runs with the blades engaged for a while (30-40 minutes), starts running rough, backfires, shuts down, and will not start. I let is cool down for about 20-30 minutes, it starts right up, runs for about 10 minutes and shuts down again. I've changed the spark plug, the filters are clean, the oil is changed, the battery is new. Please let me know what's wrong.
Thanks.

Answer
Hello Chris:

>>The Following is a Basic Instruction File I made for this. Any Input is Appreciated. I Usually Suggest you Check the Following in this Order for a Problem like yours.
>>1- Check the Gas Tank Cap and Ensure it is Venting the Tank. A Vacuum Builds in the Tank and the Gas Flow Stops or Slows (15 to 45 Minutes and if the Small Granular Sand is in the Tank it can Take Several Days of Constant Running to Bring All the Sand Particles to the Tank Outlet Port) to a Point it Shuts Off the Engine.
>>2- Operate the Equipment Until it Quits (15min to 1hr). Then Immediately Check for Fire from the Plug. If the Plug is Firing, then
>>3- Replace All the Spring Style Hose Clamps with Screw Style Hose Clamps on the Fuel System.
>>4- Check the Carburetor Solenoid. If the Carburetor Shut Off Solenoid has Current, then Remove the Carburetor Solenoid and Go to the Hardware Store. Purchase a Bolt of the Same Diameter and Threads. It Needs to be 3/4" Long. Put this Bolt in Place of the Solenoid. If this Corrects the Engine Problem, then Replace the Solenoid. ***NOTE: THIS IS FOR CHECKING THE SOLENOID ONLY I NEVER SUGGEST YOU OPERATE THE ENGINE WITH THE SOLENOID OUT OF THE CARBURETOR EXCEPT FOR TESTING PURPOSES*** Sometimes the Plunger is Moving, Just Not Far Enough to Allow the Gas to Enter the Jets.
>>5- Depending on the Model Mower, it can Also be the Pickup Tube in the Gas Tank.
>>If No Fire, then Remove the Shut Off Wire from the Coil and Check for Fire.
>>If Still No Fire, then the Ign Module or Coil is Bad. **Even if the Coil is New or Fairly New, it can Still be Bad.** On JD Mowers; Remove the Igniter/Module and the Coil and have the Local JD Dealer Test them.
>>You can View a Breakdown/IPL of the Engine and Mower at this Site Addy, http://jdpc.deere.com/jdpc/servlet/com.deere.u90490.partscatalog.view.servlets.H... and Enter the Model Numbers 1438HS and Click Find. Then Select your Model from the Search Results Area. Then Select the Sectional File. Then Select the Section of the Mower you Wish to View Online. *You can Drag the View Windows for Better Viewing.*
>>If you Hit a Snag or this Does Not Correct the Problem,  I Hope to be Here if You Require More Assistance. Hope this Helps. Let me Know What Happens, Please. May the All Mighty Bless You and Yours. Be Safe and Happy. Thanks.

Good Luck

Respectfully

John

PS: I am Allowed to Answer 5 Questions a Day. If you See I am Maxxed Out, then Try Submitting your Question at or Just After 8pm EST (US). My New Day Starts then. Comments and Ratings are Greatly Appreciated. Thanks.

Respectfully

John