Small Engines (Lawn Mowers, etc.): champion gen valve adjust, question pool, valve clearances


Question
I have a Champion 1200 generator and I'd like to adjust the valves mysefl. Where can I get the info ?

Answer
Hello Ebon:

>>Sorry for the Delay. This Question was Located in the Question Pool and I can Only Answer Questions from the Question Pool when I am Not Answering Questions here or at the Other Site I Answer Questions at.
>>I Suggest you Set the Valves at the Following Clearances First; .004in - .006in for Both Intake and Exhaust Valves  and then if there are Problems Use these Settings; .005in - .007in Intake and .009in - .011in Exhaust.
>>I have 2 of these Generators and for some Reason i have 1 Engine that Runs Perfect on the First Valve Clearances and my Other 1 has to be Set at the Second Valve Clearances. I have No Idea Why and Champion Power Equipment was of Little Assistance.
>>Please, Do Not Hesitate, If you Hit a Snag, if I Missed Something or this Does Not Correct the Problem, I am Here if You Require More Assistance. Hope this Helps. Let me Know What Happens, Please. May the All Mighty Bless You and Yours. Thanks.

Good Luck

Respectfully

John

>>PS: I am Allowed to Answer 10 Questions a Day. If you See I am Maxxed Out, then Try Submitting your Question at or Just After 8pm EST (US). My New Day Starts then. Comments and Ratings are Greatly Appreciated. Thanks.

Respectfully

John